French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
Item No.: MONM-C200
AccuPulse HandHeld NIBP Simulator
Item No.: NSCD-APHS
$0.00
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300 compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300
HandHeld NIBP Simulator & Digital Manometer
Item No.: Handheld AccuPulse
$0.00    $0.00
 

Item Details   ITEM DETAILS  

OEM ETCO2 MODULE (END-TIDAL CO2) CO2 MODULE MODEL C200 FOR MEASURING RESPIRATORY CARBON DIOXIDE CO2 SENSOR

ETCO2 Module, or end-tidal CO2, or End tidal Carbon Dioxide Module, ETCO2 Module is an OEM module used in Patient Monitors, Ventilators or Anesthesia Machine to monitor the breath status (ETCO2, CO2 waveform, Real-time CO2, Inspired CO2, Respiratory Rate) by measuring exhalant gas from people. It is useful in the ICU, surgery, anesthesia ward, emergency clinic, etc.

The ETCO2 module Model C200 is the best cost effective product in the worldwide market which helps the patient monitor manufacturers to cut the cost to quite a large extend while achieving the same or better performance and functions as the other ETCO2 modules. The ETCO2 module is a complete data collection and analysis system for monitoring respiratory carbon dioxide concentration. The Model C200 module includes a miniature CO2 sensor, barometric pressure transducer, sampling flow control and a miniature low-power vacuum pump. A microprocessor collects the sensor data and calculates various real-time parameters: instantaneous CO2 concentration, respiration rate, end-tidal CO2, inspired CO2, inspiration and expiration times.

Our sidestream ETCO2 module Model NM-C300 is newly released, you can take a look at it here

OEM ETCO2 MODULE (END-TIDAL CO2) CO2 MODULE MODEL C200 FOR MEASURING RESPIRATORY CARBON DIOXIDE CO2 SENSOR
Model Number: C200
GOLDWEI Item No.: MONM-C200
 

ELECTRICAL SPECIFICATIONS

Sensor Operating Principle InfraRed Spectroscopy
Energy Emitting Device Proprietary High Efficiency IR Source
Energy Detecting Device Frequency Stable Thermopile
CO2 Range 0% to 20%
CO2 Accuracy ±2 mmHg @ < 5.0% CO2 (at BTPS)
< 10% of reading @ >5.0% CO2 (at BTPS)
Breath Rate 2-150 BPM
Dimensions 77mm*52mm*28mm
Weight < 3.0 ounces (< 76 grams)
Operating Temperature Range 5℃ to 55℃
Shipping / Storage Temperature Range -40℃ to 70℃
Automatic Offset Calibration Time and temperature based, as well ason-demand
Input Voltage 5.00 Volts ( ±5%)
Interface Highly configurable serial digital interface(TTL/RS232), CO2 and barometric waveform data, Breath Detect Algorithm data
Pneumatics On-board aspiration pump and flow controller Configurable aspiration flows to 250 ml/min (±10%)
Power Consumption 480mW (typical with pump on) 1200mW (extreme status)
Warm-up Time 10 seconds
Response Time Detector System 38 mSec (typical)
200mSec (typical)
(Dependent Upon Implementation, Pneumatics and Water Separation Technique)

Download product manual

The ETCO2 module Model C200 (PN: MO-C200, previously NTM2.0) is the best cost effective product in the worldwide market which helps the patient monitor manufacturers to cut the cost to quite a large extend while achieving the same or better performance and functions as the other ETCO2 modules.

The OEM ETCO2 module Model C200 (previously NTM2.0) is a complete data collection and analysis system for monitoring respiratory carbon dioxide concentration. The Model C200 ETCO2 module includes a miniature CO2 sensor, barometric pressure transducer, sampling flow control and a miniature low-power vacuum pump. A microprocessor collects the sensor data and calculates various real-time parameters: instantaneous CO2 concentration, respiration rate, end-tidal CO2, inspired CO2, inspiration and expiration times. Download product manual

The module is highly configurable to meet most OEM implementation requirements. System specifications such as sampling flow rate and floating point data format can be changed by customer.

The host sends commands and receives waveform, breath parameters and command responses on two +5.0V asynchronous serial data lines (TTL or RS232).

HIGHLIGHTS


     Best performance price ratio in the world. The price is clearly lower than other similar module and the performance is better than them.
     Better stability. Better design can wipe off the excursion from temperature, pressure and inconsistent component.
     Better self- protected ability. It allows wrong power supply, humidity in the pipeline.
     Better communication interface. TTL or RS232 can be choiced by customer.
     Better policy of after service. Manufacturer promises that the module can be replaced by a new one if it is not damaged by man-made in one year.
     Longer life. Using long-life IR source (100 thousand hours life).

Related Items   RELATED ITEMS  
IBP Module B300N MOCT-B300N

The IBP Module Model B300N, the Internal version, uses PLUG & PLAY IBP TECHNOLOGY with dual-channel measurement. The IBP Module also features low-power, no extra power supply is needed, automatic digital data processing, and can repeatedly zeroing, calibration function and can be used to monitor ART, PAP, CVP, RAP, LAP, ICP and P1-P2  
Click for More Details 


Item No.: MOCT-B300N
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300 compatible with Respironics Loflo CO2 sensor

The Low Flow Sidestream ETCO2 (End-tidal CO2)Module CO2 Sensor is the ideal low sampling- rate capnography solution for your patient monitoring system. The sidestream ETCO2 Module(End-tidal CO2) Model C300 features cutting- edge technology for measurement of End-Tidal Carbon Dioxide (ETCO2) and respiratory rate. It delivers a clear, accurate capnogram at all respiratory rates up to 150 breaths per minute. With a sampling rate of 50 mL/min, it is ideal for use on adult, pediatric and infant patients; patients undergoing procedural sedation; and short- term mon-itoring of intubated patients.

Model C300 was designed to be compatible with CPT or Respironics only. If you simply want to connect to a computer and display the values on a computer screen, we can provide the development kit to allow you to use it with a computer for evaluation purpose. Our ETCO2 module is intended to work with those monitors that were designed to have the CO2 function once a Respironics Made addon module LoFlo is added. Our C300 is intended to replace the Respironics LoFlo module at a lower cost. Many manufacturers like Edan, NewTech, Contec are using the Respironics Loflo module, now they can be replaced with our C300 module at a much lower cost with better performance.

The sidestream end-tidal CO2 module is the most popular ETCO2 module in the market, the module no longer need to occupy any interior space of the hosting hardware, (monitors, breathing machine or anesthesia machine) so that the assembling of the module and the host has become very easy. The Low Flow Sidestream ETCO2 module Model C300 is easy to implement. Different from our embedded type ETCO2 module Model C002 , which usually takes a long time to evaluate whether it is going to be integrated with the host system, the Sidestream model C300 can be implemented as simple as plug & play.   
Click for More Details 


Item No.: MONM-C300

Mainstream End Tidal CO2 Sensor Model C500 compatible with Respironics Capnostat5 with 24 months warranty

The Mainstream CO2 Sensor C500 is designed for mainstream measurements using sophisticated infrared absorption spectroscopy to measure ETCO2 with mainstream, measurements are taken directly at the patients airway, so response is faster and there is less chance of erroneous, artifact data. The analyzer portion of the sensor cannot be contaminated with patient secretions, and there are no pumping or pneumatic components to replace. Maintenance requirements and overall cost-of-ownership are minimized. Our exclusive family of airway adapters are easy to use and durable enough even for long-term ventilator patients. Yet, they are inexpensive and disposable. The Mainstream CO2 Sensor C500 can be integrated with other components, software packages and accessories, making it easy for you to configure your patient monitoring systems with state-of-the-art respiratory management and analysis technology now and into the future.   
Click for More Details 


Item No.: MONM-C500
Model SP010 SPO2 Module special for New Borns or neonate (PN: MO-SP010)

The SPO2 Module SP010 is specially used in measurement of the new born baby's oxygen saturation and pulse rate. In addition to the average oxygen saturation, the SPO2 Module SP010 can send instantaneous blood oxygen saturation, especially in the sleep research very useful. the SPO2 module SP010 is compatible with all of the BCI probe. The SPO2 module SP010 can be used in infants and newborns.  
Click for More Details 


Item No.: MONM-SP010
Model SP100 SPO2 Module (PN: MO-SP100)

The SPO2 Module Model SP100 is used in the sampling inspection or measurement of the patient's oxygen saturation and pulse rate. In addition to the average oxygen saturation, low-power module can send instantaneous blood oxygen saturation, especially in the sleep research very useful. the SPO2 module Model SP100 is compatible with all of the BCI probe. The SPO2 module Model SP100 can be used in infants, newborns and adults.  
Click for More Details 


Item No.: MONM-SP100
Water trap with clip for ETCO2 module C002A or Module C200

Model 938F water trap produced by U.S. CSI is the most popular water trap in the world, and it is widely used in ETCO2 monitoring occasions. The water trap looks fine, and has reliable performance. It can not only remove the majority of water vapor during human beings breath, also has filtering capabilities, to prevent impurities going into the monitor to contaminate gas measurement sensor . The water trap which applys to the moisture content in higher level is more effectively.In accordance with the original request, one water trap must be used in a patient, not in different patients, in order to avoid cross-infection. In addition, once water trap will be filled with water, a new one must be replaced immediately to avoid the water taking in the monitor to destroy CO2 module.  
Click for More Details 


Item No.: ACCC-938F-NC
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com