French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
Item No.: MONM-C200
Patient Monitor MGW6012
Patient Monitor MGW6012
Item No.: PMKM-MGW6012
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
Item No.: MOAD-AGW0808
AccuPulse HandHeld NIBP Simulator
Item No.: NSCD-APHS
$0.00
 

Item Details   ITEM DETAILS  

MULTI-PARAMETERS PORTABLE PATIENT MONITOR MGW6012T TOUCH SCREEN WITH 5 PARAMETERS

Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage.Its size is 12.1" . It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.
MULTI-PARAMETERS PORTABLE PATIENT MONITOR MGW6012T TOUCH SCREEN WITH 5 PARAMETERS
Model Number: MGW6012T
GOLDWEI Item No.: PMKM-MGW6012T
 

Product Specification

1     ECG

 

Lead Mode                                 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection                 I, II, III, avR, avL, avF, V,

Waveform                                  2 ch

 

Lead mode                                  3 Leads ( R, L, F or RA, LA, LL)

Lead selection             I, II, III,

Waveform                                  1 ch

 

Gain                                           ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV,  auto

HR and Alarm       

                     Range    

                   Adult     15 ~ 300 bpm

                              Neo/Ped      15 ~ 350 bpm

                     Accuracy               ± 1% or ± 1bpm,which great

                     Resolution             1 bpm

                     Sensitivity             > 200 (uV P-P)

Differential Input Impedance       > 5 MΩ

CMRR

                                                 Monitor            > 105 dB

Operation         > 105 dB

                                                 Diagnosis              > 85 dB

Electrode offset potential        ±300mV

Leakage Current                          < 10 uA

Baseline Recovery                       < 3 S  After Defi.

ECG Signal Range                      ±8 m V ( Vp-p )   

Bandwidth  

Surgery          1 ~ 15 Hz

                    Monitor               0.5 ~ 35 Hz

                     Diagnostic         0.05 ~ 100 Hz

Calibration Signal                       1 (mV p-p),  Accuracy ±5% 

ST Segment Monitoring Range           

Measure and Alarm       -2.0 ~ +2.0 mV

ARR Detecting      

Type                             ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

                  Alarm                         Available

Review              Available

2     RESPARATION

Method                                      Impedance between R-F(RA-LL)

       Differential Input Impedance        >2.5 MΩ

Measuring Impedance Range:       0.3~5.0Ω

Base line Impedance Range:  0 – 2.5  KΩ

Bandwidth                                  0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range 

                                   Adult             0 ~ 120 rpm

                                   Neo/Ped         0 ~ 150 rpm

Resolution                    1 rpm

Accuracy                      ±2 rpm

Apean Alarm                              10 ~ 40 S

3     NIBP

Method                                      Oscillometric

Mode                                         Manual, Auto, STAT

Measuring Interval in AUTO Mode

       1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode   5 Min

Pulse Rate Range                         40 ~ 240 bpm

       Alarm Type                         SYS, DIA, MEAN

              Measuring and alarm range                 

             Adult Mode

SYS             40 ~ 270 mmHg

DIA                     10 ~ 215 mmHg

MEAN          20 ~ 235 mmHg

             Pediatric Mode

SYS             40 ~ 200 mmHg

DIA                     10 ~ 150 mmHg

                     MEAN         20 ~ 165 mmHg

                     Neonatal Mode

SYS             40 ~ 135 mmHg

DIA                     10 ~ 100 mmHg

MEAN          20 ~ 110 mmHg

       Resolution     

                    Pressure                1mmHg

                    

       Accuracy

                   Pressure

Maximum Mean error                 ±5mmHg

Maximum Standard deviation      ±8mmHg

       Overpressure Protection

Adult Mode                 297±3 mmHg

                     Pediatric Mode        240±3 mmHg

             Neonatal Mode            147±3 mmHg

4     SpO2

Measuring Range                         0 ~ 100 %

Alarm Range                              0 ~ 100 %

Resolution                                  1 %

Accuracy                            

                                       70% ~ 100%  ±2 %

                                         0%  ~  69%  unspecified

Actualization interval                   about 1 Sec.

       Alarm Delay                               10 Sec.

    Pulse Rate

Measuring and Alarm Range 

0~254bpm

Resolution                           1bpm

              Accuracy                             ±2bpm

5     TEMPERATURE

Channel                                      1

Measuring and Alarm Range         0 ~ 50 °C

Resolution                                  0.1°C

Accuracy                                    ±0.1°C

Actualization interval                   about 1 Sec.

    Average Time Constant                < 10 Sec.

6     IBP(Optional)

Label                                         ART, PA, CVP, RAP, LAP, ICP, P1, P2

       Measuring and alarm range

              ART                           0 ~ 300 mmHg

                                   PA                             -6 ~ 120 mmHg

                                   CVP/RAP/LAP/ICP       -10 ~ 40 mmHg

                                   P1/P2                           -10 ~ 300 mmHg                              

    Press Sensor

Sensitivity                    5  uV/V/mmHg

                     Impedance                    300-3000Ω

       Resolution                                  1 mmHg

       Accuracy                                    ±2% or ±1mmHg, which great

Actualization interval                   about 1 Sec.

 

There are no documents download yet.

Related Items   RELATED ITEMS  
Patient Monitor MGW6012

Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage.Its size is 12.1" . It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.   
Click for More Details 


Item No.: PMKM-MGW6012
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com