French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
Item No.: MOAD-AGW0808
Model MGW830 Multi-Parameter Module 6-in-1 with ECG, RESP, TEMP, NB, SPO2 OEM Board
Model MGW830 Multi-Parameter Module 6-in-1 with ECG, RESP, TEMP, NB, SPO2 OEM Board
Item No.: MOKM-MGW830
Model SP100 SPO2 Module (PN: MO-SP100)
Model SP100 SPO2 Module (PN: MO-SP100)
Item No.: MONM-SP100
Patient Monitor MGW6012
Patient Monitor MGW6012
Item No.: PMKM-MGW6012
 

Item Details   ITEM DETAILS  

NIBP MODULE MODEL NB001 (MONM-BN001)

Function 1. Numerical calculation: calculate systolic blood pressure, mean pressure, diastolic blood pressure, and pulse rate. 2. Automatic measurement mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 minutes. 3. Manual measurement mode: the user needed to manually start a measurement. 4. Calibration mode: the value of continuity in the provision of cuff pressure 5. Measurement unit: mmHg 6. Serial Communication: RS232 port, TTL-level, 4800 baud rate 7. Self checking: self-checking function available after reset
NIBP MODULE  MODEL NB001 (MONM-BN001)
Model Number: NB001
GOLDWEI Item No.: MONM-NB001
 

specifications:

 

Measuring range

Adult:
30 to 255 mmHg systolic blood pressure
An average of 20 to 235 mmHg pressure
15 to 220 mmHg diastolic blood pressure
Pulse rate of 30 to 240 times / min

 Newborn:
30 to 135 mmHg systolic blood pressure
An average of 20 to 125 mmHg pressure
15 to 110 mmHg diastolic blood pressure
Pulse Rate of 40 to 240 times / min

 Measurement time

Adults: up to more than 120 seconds;
Newborn: up to more than 90 seconds;

Restriction on software over-voltage

Adult:  Less than 290mmHg;
Newborns: no more than 145mmHg;

Protection on hardware over-voltage

Adult: 300 ±10 mmHg;
Newborn: 150 ±4 mmHg;

Measuring principle

Oscillometry

Deflation approach

ladder Deflated

The initial inflation pressure value

Adult: 150 mmHg;
Newborn: 70 mmHg;

Sensor zero reset

Prior to each measurement

Resolution

1 mmHg

Measurement accuracy

Maximum average deviation: no more than ± 5 mmHg;
maximum standard deviation: less than 8 mmHg;

Pressure accuracy instructions

± 3 mmHg

Leakage

less than 6 mmHg Per minute;

Electrical performance

Voltage: 12 VDC (adapt to the corresponding valve), 5 VDC
Quiescent current: 80 mA
Measurement current: 200 mA
inflated current: 600mA

Environment

Operating Temperature: 0 to 55 Celsius degrees
Storage Temperature: -20 to 65 Celsius degrees 
Humidity Range: 0 to 95%, non-condenser
Operation Altitude: -500 m to 4600 meters
Life Span: can operate 100,000 blood pressure measurements

Size

12.6 cm x 6.8 cm x 2.8 cm

Weight:

180 g

Characteristics:

     Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy;
    
Excellent reliability and accuracy of clinical monitoring

      The latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm;
     Capable of accomplishing all NIBP measurement items;
     Comply with CE safety design;
     Comply with all NIBP standard of ANSI/AAMI;
     Applies to adults, children and Newborn;
      5V/12V single powersupply to avoid interference with the digital circuit by the pump;
     Fully compatible with the protocol of CAS Non-invasive blood pressure module (NIBP)

 

There are no documents download yet.

Related Items   RELATED ITEMS  
NIBP Module  Model NB001 (MONM-BN001) Evaluation Kit NIBP Module Model NB001 (MONM-BN001) Evaluation Kit

NIBP Module Model NB001, Small, simple, excellent reliability and ease of installation clinical monitoring of the accuracy with the latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm, capable of accomplishing all NIBP measurement items, comply with CE safety design. The evaluation Kit includes the following items: 1) The NB001 module; 2) Lemo connector(male); 3) Lemo connector(female); 4) Extended cannula; 5) 2-way cannula commutator; 6) Cuff; 7) Cannula in instrument; 8) Power cable; 9) RS232 cable   
Click for More Details 


Item No.: MONM-NB001KIT
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |