French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
Patient Monitor MGW6012
Patient Monitor MGW6012
Item No.: PMKM-MGW6012
NIBP Module Model NB001 (MONM-BN001)
NIBP Module  Model NB001 (MONM-BN001)
Item No.: MONM-NB001
SmartSat Pulse Oximetry Analyzer
Item No.: SmartSat
$0.00
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
Item No.: MOAD-AGW0808
 

Item Details   ITEM DETAILS  

MAINSTREAM END TIDAL CO2 SENSOR MODEL C500 COMPATIBLE WITH RESPIRONICS CAPNOSTAT5 WITH 24 MONTHS WARRANTY

The Mainstream CO2 Sensor C500 is designed for mainstream measurements using sophisticated infrared absorption spectroscopy to measure ETCO2 with mainstream, measurements are taken directly at the patients airway, so response is faster and there is less chance of erroneous, artifact data. The analyzer portion of the sensor cannot be contaminated with patient secretions, and there are no pumping or pneumatic components to replace. Maintenance requirements and overall cost-of-ownership are minimized. Our exclusive family of airway adapters are easy to use and durable enough even for long-term ventilator patients. Yet, they are inexpensive and disposable. The Mainstream CO2 Sensor C500 can be integrated with other components, software packages and accessories, making it easy for you to configure your patient monitoring systems with state-of-the-art respiratory management and analysis technology now and into the future.
MAINSTREAM END TIDAL CO2 SENSOR MODEL C500 COMPATIBLE WITH RESPIRONICS CAPNOSTAT5 WITH 24 MONTHS WARRANTY
Model Number: Model C500
GOLDWEI Item No.: MONM-C500
 

The Mainstream CO2 Sensor C500 is designed for mainstream measurements using sophisticated infrared absorption spectroscopy to measure ETCO2 with mainstream, measurements are taken directly at the patients airway, so response is faster and there is less chance of erroneous, artifact data. The analyzer portion of the sensor cannot be contaminated with patient secretions, and there are no pumping or pneumatic components to replace. Maintenance requirements and overall cost-of-ownership are minimized. Our exclusive family of airway adapters are easy to use and durable enough even for long-term ventilator patients. Yet, they are inexpensive and disposable.


The Mainstream CO2 Sensor C500 can be integrated with other components, software packages and accessories, making it easy for you to configure your patient monitoring systems with state-of-the-art respiratory management and analysis technology now and into the future.

 

Below is a list of monitor brands, some of their models use the Respironics CapnoStat5 CO2 sensor, for those monitors, you can use our mainstream CO2 sensor model C500 directly without any problem, you don't even have to change anything on the software. 

AirSep, Inc. U.S.A.
BioMed Devices U.S.A.
Dixtal Biomedica Ind. Com. LTDA.Brazil
Draeger Medical USA
Fukuda Denshi Japan
GE Medical Systems Information Technology U.S.A.
Ingmar Medical, Ltd.U.S.A.
Integrated Medical U.S.A.
Larson & Toubro India
Maquet Sweden
Medical Systems Ltd. Russia
Philips Medical U.S.A.
P.P.P. EmtelPoland
Sartorius AGGermany
Sharn Veterinary U.S.A
Spacelabs MedicalU.S.A.
TaemaFrance
Vetronics U.S.A.
Vetspecs U.S.A.
Witt BioMedical U.S.A.
ZOLL Medical Corporation U.S.A.

 

Transducer Type

Mainstream CO2 Sensor

 Principle of Operation

Infrared Spectroscopy

Energy Emitting Device

Proprietary High Efficiency IR Source

Energy Detecting Device

Frequency Stable Thermopile

CO2 Measurement Range

0% to 20%

CO2 Resolution

0.1 mm Hg 0 to 49 mm Hg

0.2 mm Hg 50 to 150 mm Hg

CO2 Accuracy

 ±2 mm Hg  @ < 5.0% CO2 (at BTPS)
< 10% of reading @ > 5.0%CO2(at BTPS)

Dimensions

50mm*22mm*36mm

Weight 

 < 40g

Breath  Rate Range

2 to 150 Breaths Per Minute (BPM)

Respiratory Rate Accuracy

±1 breath

Calibration

No routine user calibration required, but module can be calibrated by user

Data Interface

Highly configurable serial digital interface (TTL/RS232 Level)

Data Output

CO2 gas concentration (mm Hg), End-tidal CO2, Inspired CO2, Respiratory Rate.

Input Voltage 

5.0 VDC ±5%

Power Consumption

400mW

Warmup Time

 10 seconds

Response Time

 Detector: 20mSec (Typical)

 System: 200mSec(Typical)

Operating Temperature

5º to 50ºC

Shipping/Storage
Temperature Range

 -40º to 70ºC

Interconnection

Standard Lemo Redel 8-pin plastic
Material PSU
Sensor Plug: PAB.M0.8GL.AC39GZ
Band Relief: GMA.1B.030.DJ
Host Receptacle: PKB.M0.8GL.LJ

Note:

Pin out:

1 VA 5.0V
2 Shield Shield
3 DGND Digital return
4 VA 5.0V
5 TxD Serial data from the Module
6 RxD Serial data from Host
7 AGND Analog return
8 NC

Shock Impact

IEC TR 6 0721-4-7 Class 7M3 (designed to withstand environments subject to significant vibrations or high shock levels)

EN6 0068-2-27 Shock

EN60068-2-64 Random vibration

Regulatory

Designed to meet IEC 6 0601-1-2 , EN55011 ?CISPIR 11 Class B (Radiated and Conductive Emissions),

IEC 6 1000-4-2 Electrostatic Discharge Immunity, IEC 6 1000-4-3 Radiated Immunity, Designed to comply

with 93/42/EEC (MDD CE Marking), FDA Standards, Minimum Performance and Safety Requirements for

Capnometers and ISO21647. Medical Electrical Equipment performance requirements for the basic safety

and essential performance of respiratory gas monitors.

 

KEY FEATURES:

  • 100% compatible with Respironics CapnoStat5
  • Response is faster and there is less chance of erroneous, artifact data
  • Long-lasting life for the infrared light receiver
  • There are no pumping or pneumatic components to replace thus maintenance requirements and overall cost-of-ownership are minimized
  • More affordable and economical
  • Clinical waveform recoganition ability is stronger with better performance

 

There are no documents download yet.

Related Items   RELATED ITEMS  
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300 compatible with Respironics Loflo CO2 sensor

The Low Flow Sidestream ETCO2 (End-tidal CO2)Module CO2 Sensor is the ideal low sampling- rate capnography solution for your patient monitoring system. The sidestream ETCO2 Module(End-tidal CO2) Model C300 features cutting- edge technology for measurement of End-Tidal Carbon Dioxide (ETCO2) and respiratory rate. It delivers a clear, accurate capnogram at all respiratory rates up to 150 breaths per minute. With a sampling rate of 50 mL/min, it is ideal for use on adult, pediatric and infant patients; patients undergoing procedural sedation; and short- term mon-itoring of intubated patients.

Model C300 was designed to be compatible with CPT or Respironics only. If you simply want to connect to a computer and display the values on a computer screen, we can provide the development kit to allow you to use it with a computer for evaluation purpose. Our ETCO2 module is intended to work with those monitors that were designed to have the CO2 function once a Respironics Made addon module LoFlo is added. Our C300 is intended to replace the Respironics LoFlo module at a lower cost. Many manufacturers like Edan, NewTech, Contec are using the Respironics Loflo module, now they can be replaced with our C300 module at a much lower cost with better performance.

The sidestream end-tidal CO2 module is the most popular ETCO2 module in the market, the module no longer need to occupy any interior space of the hosting hardware, (monitors, breathing machine or anesthesia machine) so that the assembling of the module and the host has become very easy. The Low Flow Sidestream ETCO2 module Model C300 is easy to implement. Different from our embedded type ETCO2 module Model C002 , which usually takes a long time to evaluate whether it is going to be integrated with the host system, the Sidestream model C300 can be implemented as simple as plug & play.   
Click for More Details 


Item No.: MONM-C300

OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor

ETCO2 Module, or end-tidal CO2, or End tidal Carbon Dioxide Module, ETCO2 Module is an OEM module used in Patient Monitors, Ventilators or Anesthesia Machine to monitor the breath status (ETCO2, CO2 waveform, Real-time CO2, Inspired CO2, Respiratory Rate) by measuring exhalant gas from people. It is useful in the ICU, surgery, anesthesia ward, emergency clinic, etc.

The ETCO2 module Model C200 is the best cost effective product in the worldwide market which helps the patient monitor manufacturers to cut the cost to quite a large extend while achieving the same or better performance and functions as the other ETCO2 modules. The ETCO2 module is a complete data collection and analysis system for monitoring respiratory carbon dioxide concentration. The Model C200 module includes a miniature CO2 sensor, barometric pressure transducer, sampling flow control and a miniature low-power vacuum pump. A microprocessor collects the sensor data and calculates various real-time parameters: instantaneous CO2 concentration, respiration rate, end-tidal CO2, inspired CO2, inspiration and expiration times.

Our sidestream ETCO2 module Model NM-C300 is newly released, you can take a look at it here  
Click for More Details 


Item No.: MONM-C200

Water trap with clip for ETCO2 module C002A or Module C200

Model 938F water trap produced by U.S. CSI is the most popular water trap in the world, and it is widely used in ETCO2 monitoring occasions. The water trap looks fine, and has reliable performance. It can not only remove the majority of water vapor during human beings breath, also has filtering capabilities, to prevent impurities going into the monitor to contaminate gas measurement sensor . The water trap which applys to the moisture content in higher level is more effectively.In accordance with the original request, one water trap must be used in a patient, not in different patients, in order to avoid cross-infection. In addition, once water trap will be filled with water, a new one must be replaced immediately to avoid the water taking in the monitor to destroy CO2 module.  
Click for More Details 


Item No.: ACCC-938F-NC
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com