PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
NIBP Module Model NB001 (MONM-BN001)
NIBP Module  Model NB001 (MONM-BN001)
Item No.: MONM-NB001
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300M compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300M
$0.00
SmartSat Pulse Oximetry Analyzer
Item No.: SmartSat
$0.00
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
Item No.: MONM-C200
 

Item Details   ITEM DETAILS  

STEREOTACTIC NEEDLE BIOPSYTRAINING PHANTOM MODEL 013

The Stereotactic Needle Biopsy Training Phantom is a disposable training tool and practice medium for mammographic needle biopsy procedures. The phantom also serves as an excellent quality assurance device for stereotactic systems and should be used whenever a new system is installed or repaired to insure accurate needle placement. The phantom can be used to perform the localization accuracy test in the American College of Radiology's stereotactic breast biopsy accreditation program.
STEREOTACTIC NEEDLE BIOPSYTRAINING PHANTOM MODEL 013
Model Number: Model 013
GOLDWEI Item No.: MMCS-013
 

Stereotactic Needle Biopsy
Training Phantom

A tissue equivalent, compressible
biopsy training phantom, that wont leak


Model 013


Features
• Compressible
• Does not leak when punctured
• Contains various sizes of dense masses for biopsy
• Contains calcification clusters for visualization and biopsy
• Anthropomorphic shape for accurate simulation of breast compression
• Simulates needle resistance
• Palpable lesions
• Physical consistency similar to human tissue
• Compatible with both stand alone and add-on stereotactic biopsy systems
• Works on digital systems




The CIRS Stereotactic Needle Biopsy Training Phantom is a disposable training tool and practice medium for mammographic needle biopsy procedures. The phantom also serves as an excellent quality assurance device for stereotactic systems and should be used whenever a new system is installed or repaired to insure accurate needle placement. The phantom can be used to perform the localization accuracy test in the American College of Radiology's stereotactic breast biopsy accreditation program.

The phantom body is shaped to represent a partially compressed breast. This allows the user to easily compress the breast to 4.5 cm thickness for optimum imaging. The shape also enables the phantom to be used in systems where the patient is either prone or sitting. The phantom is made from a proprietary gel with a physical consistency similar to human tissue and, since the gel is a non-flowing material, it won't leak out when punctured. The gel is surrounded by an elastic skin-like membrane, which enables palpation of the embedded masses and provides needle resistance.

Embedded within the phantom are numerous solid masses in a range of sizes. These radiographically visible masses can be biopsied multiple times. The masses are colored black for easy visualization of a successful biopsy. These solid masses are randomly positioned so each phantom provides a unique training experience. Two calcification clusters are positioned within the medial transverse plane at the right and left edge of the phantom. These calcifications can be biopsied or used for QA checks on the mammography system. To aid in visualizing the location of the calcifications, the two groups are each clustered around a white but radiographically transparent mass.

The stereotactic training phantom offers an easy, low cost option to create a relaxed learning environment. The phantom can be reused multiple times with no special storage requirements. The CIRS Model 013 Stereotactic Needle Biopsy Training Phantom provides a simple training solution for mammographic needle biopsy procedures.


Stereotactic Needle Biopsy Training Phantom A tissue equivalent, compressible biopsy training phantom, that wont leak Model 013 Features ?Compressible ?Does not leak when punctured ?Contains various sizes of dense masses for biopsy ?Contains calcification clusters for visualization and biopsy ?Anthropomorphic shape for accurate simulation of breast compression ?Simulates needle resistance ?Palpable lesions ?Physical consistency similar to human tissue ?Compatible with both stand alone and add-on stereotactic biopsy systems ?Works on digital systems The CIRS Stereotactic Needle Biopsy Training Phantom is a disposable training tool and practice medium for mammographic needle biopsy procedures. The phantom also serves as an excellent quality assurance device for stereotactic systems and should be used whenever a new system is installed or repaired to insure accurate needle placement. The phantom can be used to perform the localization accuracy test in the American College of Radiology's stereotactic breast biopsy accreditation program. The phantom body is shaped to represent a partially compressed breast. This allows the user to easily compress the breast to 4.5 cm thickness for optimum imaging. The shape also enables the phantom to be used in systems where the patient is either prone or sitting. The phantom is made from a proprietary gel with a physical consistency similar to human tissue and, since the gel is a non-flowing material, it won't leak out when punctured. The gel is surrounded by an elastic skin-like membrane, which enables palpation of the embedded masses and provides needle resistance. Embedded within the phantom are numerous solid masses in a range of sizes. These radiographically visible masses can be biopsied multiple times. The masses are colored black for easy visualization of a successful biopsy. These solid masses are randomly positioned so each phantom provides a unique training experience. Two calcification clusters are positioned within the medial transverse plane at the right and left edge of the phantom. These calcifications can be biopsied or used for QA checks on the mammography system. To aid in visualizing the location of the calcifications, the two groups are each clustered around a white but radiographically transparent mass. The stereotactic training phantom offers an easy, low cost option to create a relaxed learning environment. The phantom can be reused multiple times with no special storage requirements. The CIRS Model 013 Stereotactic Needle Biopsy Training Phantom provides a simple training solution for mammographic needle biopsy procedures.