French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
Item No.: MONM-C200
Patient Monitor MGW6012
Patient Monitor MGW6012
Item No.: PMKM-MGW6012
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
Item No.: MOAD-AGW0808
AccuPulse HandHeld NIBP Simulator
Item No.: NSCD-APHS
$0.00
 

Item Details   ITEM DETAILS  

PATIENT SIMULATORS-MINISIM- BASIC - ARRHYTHMIA SIMULATOR

The MiniSim Basic, Arrhythmia Simulator is a powerful, comprehensive but basic patient simulator in a compact case. It is designed for testing the performance of basic patient monitoring instrumentation quickly and easily. The microprocessor based instrument is menu driven via its tactile feel keypad and easy to follow LCD display. The MiniSim 1000 provides full 12 lead ECG simulation with 14 user selectabel rates from 30 to 350 BPM and 14 user selectable amplitudes from 0.15 to 5 mV. Sine, Square, and Triangle performance waveforms are simulated with 14 user selectable rates from 0.1 to 100 Hz.The MiniSim also simulates 45 different arrhythmias including atrial, ventricular, tall T wave, ST elevation, ST depression, myocardial infraction, blocks, pulse, and pacer waveforms.
PATIENT SIMULATORS-MINISIM- BASIC - ARRHYTHMIA SIMULATOR
Model Number:
GOLDWEI Item No.: PSNE Basic1000
 

Features

Easy to Use
Small, Compact Size
Menu driven operatoin
Large LCD Display
Tactile Keypad
Battery or AC Operation

 
Specfications
ECG: 12 leads with independent outputs referenced to RL.

NORMAL SINUS RHYTHM (NSR)

ECG Rates: 30, 60, 70, 80, 90, 100, 120, 150, 180, 210, 240, 270, 300, and 350 BPM. Accuracy 0.5%.

Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II. Lead 1 is 0.6 X Lead II, Lead III is 0.4 X Lead II, and Lead V is the same as Lead II.

High Level: 500 X low level output on Lead II.

Accuracy: 2% (1-5mV).

PERFORMANCE WAVEFORMS (PERF)

Sine, Square, Triangle, Pulse

Frequencies: 0.1 to 0.9 in 0.1 Hz steps.

1.0 to 9.0 in 1.0 Hz steps.

10 to 100 in 10 Hz steps.

Accuracy: 1%

Amplitudes: 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II.

Pulse: 20 ms pulse of 1mV amplitude repeated at 4 second intervals.

R WAVE DETECTION (RWD)

Widths: 10, 40, 50, 60, 70, 80, 90, 100, 110, and 120 ms.

Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mV on Lead II.

PACER (PCR)

AP: Atrial Pacer set at 70 BPM.

ASP: Asynchronous Pacer - Ineffective Pacing.

Pacer Amplitudes: + 2 mV and - 2mV.

QRS Amplitudes: 1 mV

PCR: Pacer pulses alone.

Pacer Widths: 0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 ms.

Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV.

VP: Ventricular Pacer set at 70 BPM.

AVP: Atrial Ventricular Pacer set at 70 BPM.

QRS Amplitude: 1 mV.

Pacer Amplitude: -2mV.

POWER REQUIRMENTS:

One 9 Volt alkaline battery or optional AC adapter.

PHYSICAL CHARACTERISTICS:

Dimensions: 5.5 X 3.5 X 1.5 inches (13.9 X 8.9 X 3.8 cm).

Weight: 10 oz ( 0.3 kg).

TEMPERATURE REQUIREMENTS:

Operating: 59 to 95 Degrees F (15 to 35 Degrees C).

Storage: 32 to 131 Degrees F (0 to 55 Degrees C).

 

There are no documents download yet.

Related Items   RELATED ITEMS  
BioSim12 ECG simulator ECG signal generator

BioSim 12 ECG simulator, Outputs synchronous and standard ECG signals by 12 leads, ECG Rate: 40BPM to 160BPM (optional), Amplitude: 0.1 to 2.0mV, and the increment is 0.1 (optional); It can output 19 important and normal arrhythmia waves forms. All the arrhythmia waves are synchronous 12 leads. The Biosim12 Can superimpose stochastic noise on any ECG wave and superimpose polarized voltage on any waveform (±300mv).   
Click for More Details 


Item No.: PSNM-BIOSIM12
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com