BEST SELLERS
AccuPulse HandHeld NIBP Simulator
Item No.: NSCD-APHS
$0.00
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300 compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300
HandHeld NIBP Simulator & Digital Manometer
Item No.: Handheld AccuPulse
$0.00    $0.00
MULTI-PARAMETER MODULE 7-IN-1 MODEL AGW0808 Parameter board and Main Board Integrated
Item No.: MOAD-AGW0808
 

Item Details   ITEM DETAILS  

MODEL MGW830 MULTI-PARAMETER MODULE 6-IN-1 WITH ECG, RESP, TEMP, NB, SPO2 EVALUATION KIT

The MGW830 parameters boards include measure circuits of physical parameters, as ECG, RESP, NIBP, SPO2, Temp1, Temp2, IBP (optional), etc., with higher plane of custody system available for ECG, RESP, Temp, NB, SPO2, USA, and other physical parameters for guardianship of adults, children, neonatal patients. Its characteristics include: the adoption of a CPU controls seven parameters functional modules with high master degrees, high reliability, high performance, low-cost, low consumption, small size, it is the best options for patient monitor. This is the evaluation kit including all necessary accessories for research and development design purpose.
MODEL MGW830 MULTI-PARAMETER MODULE 6-IN-1 WITH ECG, RESP, TEMP, NB, SPO2 EVALUATION KIT
Model Number: MGW830KIT
GOLDWEI Item No.: MOKM-MGW830KIT
 

The MGW830 parameters boards include measure circuits of physical parameters, as ECG, RESP, NIBP, SPO2, Temp , IBP (optional), CO2 (optional), CO (optional), IBP (options), ECG (12 leads, optional) etc., with higher plane of custody system available for ECG, RESP, Temp, NB, SPO2, and other physical parameters for guardianship of adults, children, neonatal patients.

 

Its characteristics include: the adoption of a CPU controls seven parameters functional modules with high master degrees, high reliability, high performance, low-cost, low consumption, small size, it is the best options for patient monitor.

 

MGW830 parameters board can get communication with the CPU system through a serial port. It can provide real-time 2 ECG waveform, 1 SPO2 waveform, data of 1 RESP waveform and 2 IBP waveform, through analysis, it can provide data of HR and ST, and physical parameters as RR, SPO2, PR, NIBP (Systolic, Diastolic, Mean pressure) and IBP (Systolic, Diastolic, Mean pressure).

The module can be easily integrated to the whole sets of the monitor equipment after specially designed.

 

Specifications

Classification

Anti-electroshock type

Class I

Anti-electroshock degree

CF   anti-tremble proof

Apply standard

GB 9706.1-2007

the first part of medical wiring:safety currency

YY0089-92

patient monitoring system special safety

request YY1079-2008:

Special mark of ECG monitor

ANSI/AAMI/IEC 60601-2-21

medical electrical equipment –part 2:

&60601-2-21 Amendment 1:2000

Particular requirements for the safety of infant radiant warmers

ANSI/AAMI EC13:2002

“Cardiac monitors, heart rate meters, and alarms”

60601-2-37

Medical electrical equipment Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment

The module follow below level:

EN ISO 9001, EN 46001, EN 1441, prEN1041, EN980, IEC878, EN ISO 10993-1, EN540, EN 60601-1, EN60601-1-2, EN60601-1-4, EN 60601-2-27, EN 60601-2-30, EN 60601-2-34, EN475, EN865, EN12470, 60601-2-34, EN475, EN865, EN12470,

Size and Weight

Size / Weight

120mm x100mm x 25mm  /  < 300 g (not include accessories)

Power supply

Request of exterior power supply:input voltage 12V DC(±10%), 0.5A, lines wave <100mv, Power consumption:static state < 2W, work < 6WIsolated:4000VAC     Leak current  <0.5mA

Input/output connection

Choose RS232 and TTL connection through asynchrony serial port

Temperature Range

Working

0 ~ 55°C

Storage

-20 ~ 65 °C

Humidity Range

Working

15% 95 % no coagulate

Storage

10% 95 %no coagulate

ECG Specification

Standard 3 or 5 lead cable

3 lead

RA,LA,LL, lead mode:I, II, III

5 lead

RA,LA,LL,RL,V, lead mode:I, II, III, aVR, aVL, aVF, V

Gain

´250, ´500, ´1000, ´2000

HR   Range

Adult

15 ~ 300 BPM

Neo/Ped

15 ~ 350 BPM

Accuracy      

± 1% or ± 1bpm, choose the greater one

Resolution

1BPM

Sensitivity

> 200 (µV P-P)

Input Impedance

> 5 MΩ

Bandwidth

Diagnostic / Monitor / Surgery

0.05 ~ 130 Hz / 0.5 ~ 40 Hz / 1 ~ 20 Hz

Common module restrain ratio

Diagnostic

 > 90 dB

Monitor

 > 100 dB

Electrode polarize voltage range

±300mV

Survey pace-making pulse with the following condition:

Range:

±2 mV ±700mV\

Width:

0.1ms 2ms

Rise time:

10us100µs

Restrain the pace-making pulse

Range:

±2 mV ±700mV

Width:

0.1ms 2ms

Rise time:

10us 100µs

Baseline Renew time

< 3 s after defibrillation

Signal Range

±8 mV (P-P)

Calibration Signal

1 (mV p-p),  Accuracy :±5% 

Segment Survey Measure

Measure range:

-2.0mV +2.0mV

Accuracy:

-0.8 mV+0.8mV error within range is ±0.02mV or ±10% take the greater one Other range is not defined

RESP Specification

Measure Method

 Impedance between R-F (RA-LL)

Measuring RESP Impedance Range:

0.    3~3Ω

Base line Impedance Range:

2004000Ω

Bandwidth

0.     12.5Hz

RESP Rate

Adult

7120BrPM  

Neo/Ped

150 BrPM

Resolution

1 BrPM

Accuracy      

±2 BrPM

Apnea Alarm

1040s

NIBP Specification

Measure method

Pulse wave Oscillometric

Work mode

Manual/auto/ STAT

Measuring Interval in AUTO Mode

 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes

Measuring Period in STAT Mode

5 Min

Pulse Rate Range

40 ~ 240 BPM

Measuring Range and Accuracy      

Adult Mode

SYS

40 ~ 270mmHg

DIA

10 ~ 215 mmHg

MEAN

20 ~ 235 mmHg

Pediatric Mode

SYS

40 ~ 200 mmHg

DIA

10 ~ 150 mmHg

MEAN

20 ~ 165 mmHg

Neonatal Mode

SYS

40 ~ 135 mmHg

DIA

10 ~ 100 mmHg

MEAN

20 ~ 235 mmHg

static state pressure range

0300mmHg

Static state pressure accuracy

±3mmHg

Overpressure Protection

Adult Mode

300 mmHg

Pediatric Mode

240mmHg

Neonatal Mode

150 mmHg

SPO2 Saturation

Measuring Range

0 ~ 100 %

Resolution

1 %

Accuracy

70100%:±2 DIGIT     0%  ~ 69% unspecified

Pulse Rate

Measuring Range

20300bpm

Resolution

1BPM

Accuracy

±3bpm

TEMP Specification

Available TEMP sensor

YSI, CYF

Channel number

2 channels

Measuring

Range

0 ~ 50 °C

Resolution

0.1°C

Accuracy

±0.1°C(not include sensor error)

IBP Specification

Channel number

2 channels

pressure names

 ART, PA, CVP, RAP, LAP, ICP, P1, P2

Pressure Measuring range

ART

0 300 mmHg

PA  

-6 120 mmHg

CVP

-10 40 mmHg

RAP

-10 40 mmHg

LAP

-10 40 mmHg

ICP 

-10 40 mmHg

P1, P2

-10 300 mmHg

Accuracy

± 1mmHg or ± 2%, take the greater one (not include sensor error)

Press Sensor

Sensitivity

5 μV/V/mmHg

Impedance

300-3000Ω

 

There are no documents download yet.

Related Items   RELATED ITEMS  
Model MGW830 Multi-Parameter Module 6-in-1 with ECG, RESP, TEMP, NB, SPO2 OEM Board

The MGW830 parameters boards include measure circuits of physical parameters, as ECG, RESP, NIBP, SPO2, Temp1, Temp2, IBP (optional), etc., with higher plane of custody system available for ECG, RESP, Temp, NB, SPO2, USA, and other physical parameters for guardianship of adults, children, neonatal patients. Its characteristics include: the adoption of a CPU controls seven parameters functional modules with high master degrees, high reliability, high performance, low-cost, low consumption, small size, it is the best options for patient monitor.  
Click for More Details 


Item No.: MOKM-MGW830
Model MGW830 Multi-parameter Patient Monitor (include main board, multi parameter module and every necessary accessories)

The MGW830 parameters boards include measure circuits of physical parameters, as ECG, RESP, NIBP, SPO2, Temp1, Temp2,IBP (optional), etc., with higher plane of custody system available for ECG, RESP, Temp, NB, SPO2, USA, and other physical parameters for guardianship of adults, children, neonatal patients. Its characteristics include: the adoption of a CPU controls seven parameters functional modules with high master degrees, high reliability, high performance, low-cost, low consumption, small size, it is the best options for patient monitor. This is the evaluation machine developed based upon the MGW830 board. Evaluation machine includes the main board, multi parameter module and all the necessary accessories.  
Click for More Details 


Item No.: MOKM-MGW830M
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com