ITEM DETAILS |
|
|
|
MODEL MGW830 MULTI-PARAMETER MODULE 6-IN-1 WITH ECG, RESP, TEMP, NB, SPO2 EVALUATION KIT |
The MGW830 parameters boards include measure
circuits of physical parameters, as ECG, RESP,
NIBP, SPO2, Temp1, Temp2, IBP
(optional), etc., with higher plane of custody
system available for ECG, RESP, Temp, NB, SPO2,
USA, and other physical parameters for
guardianship of adults, children, neonatal
patients.
Its characteristics include: the adoption of a CPU
controls seven parameters functional modules with
high master degrees, high reliability, high
performance, low-cost, low consumption, small
size, it is the best options for patient monitor.
This is the evaluation kit including all necessary
accessories for research and development design
purpose. |
|
Model Number:
MGW830KIT
GOLDWEI Item No.:
MOKM-MGW830KIT
|
|
|
|
The MGW830 parameters boards include measure circuits of physical parameters, as ECG, RESP, NIBP, SPO2, Temp , IBP (optional), CO2 (optional), CO (optional), IBP (options), ECG (12 leads, optional) etc., with higher plane of custody system available for ECG, RESP, Temp, NB, SPO2, and other physical parameters for guardianship of adults, children, neonatal patients.
Its characteristics include: the adoption of a CPU controls seven parameters functional modules with high master degrees, high reliability, high performance, low-cost, low consumption, small size, it is the best options for patient monitor.
MGW830 parameters board can get communication with the CPU system through a serial port. It can provide real-time 2 ECG waveform, 1 SPO2 waveform, data of 1 RESP waveform and 2 IBP waveform, through analysis, it can provide data of HR and ST, and physical parameters as RR, SPO2, PR, NIBP (Systolic, Diastolic, Mean pressure) and IBP (Systolic, Diastolic, Mean pressure).
The module can be easily integrated to the whole sets of the monitor equipment after specially designed.
Specifications
Classification |
Anti-electroshock type |
Class I |
Anti-electroshock degree |
CF anti-tremble proof |
Apply standard |
GB 9706.1-2007 |
the first part of medical wiring:safety currency |
YY0089-92 |
patient monitoring system special safety |
request YY1079-2008: |
Special mark of ECG monitor |
ANSI/AAMI/IEC 60601-2-21 |
medical electrical equipment –part 2: |
&60601-2-21 Amendment 1:2000 |
Particular requirements for the safety of infant radiant warmers |
ANSI/AAMI EC13:2002 |
“Cardiac monitors, heart rate meters, and alarms” |
60601-2-37 |
Medical electrical equipment Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment |
The module follow below level: |
EN ISO 9001, EN 46001, EN 1441, prEN1041, EN980, IEC878, EN ISO 10993-1, EN540, EN 60601-1, EN60601-1-2, EN60601-1-4, EN 60601-2-27, EN 60601-2-30, EN 60601-2-34, EN475, EN865, EN12470, 60601-2-34, EN475, EN865, EN12470, |
Size and Weight |
Size / Weight |
120mm x100mm x 25mm / < 300 g (not include accessories) |
Power supply |
Request of exterior power supply:input voltage 12V DC(±10%), 0.5A, lines wave <100mv, Power consumption:static state < 2W, work < 6W。Isolated:4000VAC Leak current <0.5mA |
Input/output connection |
Choose RS232 and TTL connection through asynchrony serial port |
Temperature Range |
Working |
0 ~ 55°C |
Storage |
-20 ~ 65 °C |
Humidity Range |
Working |
15% ~ 95 % (no coagulate) |
Storage |
10% ~ 95 %(no coagulate) |
ECG Specification |
Standard 3 or 5 lead cable |
3 lead |
RA,LA,LL, lead mode:I, II, III |
5 lead |
RA,LA,LL,RL,V, lead mode:I, II, III, aVR, aVL, aVF, V |
Gain |
´250, ´500, ´1000, ´2000 |
HR Range |
Adult |
15 ~ 300 BPM |
Neo/Ped |
15 ~ 350 BPM |
Accuracy |
± 1% or ± 1bpm, choose the greater one |
Resolution |
1BPM |
Sensitivity |
> 200 (µV P-P) |
Input Impedance |
> 5 MΩ |
Bandwidth |
Diagnostic / Monitor / Surgery |
0.05 ~ 130 Hz / 0.5 ~ 40 Hz / 1 ~ 20 Hz |
Common module restrain ratio |
Diagnostic |
> 90 dB |
Monitor |
> 100 dB |
Electrode polarize voltage range |
±300mV |
Survey pace-making pulse with the following condition: |
Range: |
±2 mV ~ ±700mV\ |
Width: |
0.1ms ~ 2ms |
Rise time: |
10us~100µs |
Restrain the pace-making pulse |
Range: |
±2 mV ~ ±700mV |
Width: |
0.1ms ~ 2ms |
Rise time: |
10us ~ 100µs |
Baseline Renew time |
< 3 s after defibrillation |
Signal Range |
±8 mV (P-P) |
Calibration Signal |
1 (mV p-p), Accuracy :±5% |
Segment Survey Measure |
Measure range: |
-2.0mV ~ +2.0mV |
Accuracy: |
-0.8 mV~+0.8mV error within range is ±0.02mV or ±10% take the greater one Other range is not defined |
RESP Specification |
Measure Method |
Impedance between R-F (RA-LL) |
Measuring RESP Impedance Range: |
0. 3~3Ω |
Base line Impedance Range: |
200~4000Ω |
Bandwidth |
0. 1~2.5Hz |
RESP Rate |
Adult |
7~120BrPM |
Neo/Ped |
~150 BrPM |
Resolution |
1 BrPM |
Accuracy |
±2 BrPM |
Apnea Alarm |
10~40s |
NIBP Specification |
Measure method |
Pulse wave Oscillometric |
Work mode |
Manual/auto/ STAT |
Measuring Interval in AUTO Mode |
1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes |
Measuring Period in STAT Mode |
5 Min |
Pulse Rate Range |
40 ~ 240 BPM |
Measuring Range and Accuracy |
Adult Mode |
SYS |
40 ~ 270mmHg |
DIA |
10 ~ 215 mmHg |
MEAN |
20 ~ 235 mmHg |
Pediatric Mode |
SYS |
40 ~ 200 mmHg |
DIA |
10 ~ 150 mmHg |
MEAN |
20 ~ 165 mmHg |
Neonatal Mode |
SYS |
40 ~ 135 mmHg |
DIA |
10 ~ 100 mmHg |
MEAN |
20 ~ 235 mmHg |
static state pressure range |
0~300mmHg |
Static state pressure accuracy |
±3mmHg |
Overpressure Protection |
Adult Mode |
300 mmHg |
Pediatric Mode |
240mmHg |
Neonatal Mode |
150 mmHg |
SPO2 Saturation |
Measuring Range |
0 ~ 100 % |
Resolution |
1 % |
Accuracy |
70~100%:±2 DIGIT 0% ~ 69% unspecified |
Pulse Rate |
Measuring Range |
20~300bpm |
Resolution |
1BPM |
Accuracy |
±3bpm |
TEMP Specification |
Available TEMP sensor |
YSI, CYF |
Channel number |
2 channels |
Measuring |
Range |
0 ~ 50 °C |
Resolution |
0.1°C |
Accuracy |
±0.1°C(not include sensor error) |
IBP Specification |
Channel number |
2 channels |
pressure names |
ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Pressure Measuring range |
ART |
0 ~ 300 mmHg |
PA |
-6 ~ 120 mmHg |
CVP |
-10 ~ 40 mmHg |
RAP |
-10 ~ 40 mmHg |
LAP |
-10 ~ 40 mmHg |
ICP |
-10 ~ 40 mmHg |
P1, P2 |
-10 ~ 300 mmHg |
Accuracy |
± 1mmHg or ± 2%, take the greater one (not include sensor error) |
Press Sensor |
Sensitivity |
5 μV/V/mmHg |
Impedance |
300-3000Ω |
There are no documents download yet.
|
|
|
RELATED ITEMS |
|
|
|
Model MGW830 Multi-Parameter Module 6-in-1 with ECG, RESP, TEMP, NB, SPO2 OEM Board
The MGW830 parameters boards include measure circuits of physical parameters, as ECG, RESP, NIBP, SPO2, Temp1, Temp2, IBP
(optional), etc., with higher plane of custody system available for ECG, RESP, Temp, NB, SPO2, USA, and other physical parameters for guardianship of adults, children, neonatal patients.
Its characteristics include: the adoption of a CPU controls seven parameters functional modules with high master degrees, high reliability, high performance, low-cost, low consumption, small size, it is the best options for patient monitor. Click for More Details
Item No.: MOKM-MGW830
|
|
|
|
|
Model MGW830 Multi-parameter Patient Monitor (include main board, multi parameter module and every necessary accessories)
The MGW830 parameters boards include measure circuits of physical parameters, as ECG, RESP, NIBP, SPO2, Temp1, Temp2,IBP
(optional), etc., with higher plane of custody system available for ECG, RESP, Temp, NB, SPO2, USA, and other physical parameters for guardianship of adults, children, neonatal patients.
Its characteristics include: the adoption of a CPU controls seven parameters functional modules with high master degrees, high reliability, high performance, low-cost, low consumption, small size, it is the best options for patient monitor.
This is the evaluation machine developed based upon the MGW830 board. Evaluation machine includes the main board, multi parameter module and all the necessary accessories. Click for More Details
Item No.: MOKM-MGW830M
|
|
|
|
|
|