Features:
![](../img/icored-b.gif)
5 Leads 7 channel ECG
![](../img/icored-b.gif)
Data Graph and Trend Table Review
![](../img/icored-b.gif)
Alarm Event Review
![](../img/icored-b.gif)
ST segment detection
![](../img/icored-b.gif)
Arrhythmia analysis
![](../img/icored-b.gif)
Freeze and review
![](../img/icored-b.gif)
Convenient operation by touch screen
![](../img/icored-b.gif)
13 arrhythmia classification and 2-channel ST segment analysis
![](../img/icored-b.gif)
Large SD card memory for more than 2000 patient cases storage
![](../img/icored-b.gif)
Sync with PC based Software (WinXP and WinVista)
Performance Specifications
![](../img/icored-b.gif)
Display:3.5" Color TFT
![](../img/icored-b.gif)
Resolution:320x240
![](../img/icored-b.gif)
Display Mode:Standard face, Multi-ECG face,Big Num face
![](../img/icored-b.gif)
Indicator:Power indicator light, Alarm Sound,Heart Beat Tone
![](../img/icored-b.gif)
Interface:One dual-purpose socket for connecting ECG sensors and sync communication cables
![](../img/icored-b.gif)
Power Supply:DC 5V, <300mA
![](../img/icored-b.gif)
Battery:Builtin Li-Polymer, 2 hours for charging,4 hours for continous working.
![](../img/icored-b.gif)
Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
![](../img/icored-b.gif)
Trend Table:Resolution from 1s, 5s, 10s. Review up to 2000 patient cases.
![](../img/icored-b.gif)
Alarm:Ajustable High and Low limits. Three level audible and vistual alarm
![](../img/icored-b.gif)
User Configuration:All the color of parameters and waves can be set according to user's willing
![](../img/icored-b.gif)
Technical specifications:
![](../img/icored-b.gif)
Safety
![](../img/icored-b.gif)
Meet the requirment of IEC60601 series
![](../img/icored-b.gif)
Type of Protection:Class II with internal electirc power supply
![](../img/icored-b.gif)
Degree of Protection:CF
![](../img/icored-b.gif)
Dimention and Weight
![](../img/icored-b.gif)
Dimention:92(W)x82(H)x22(D)mm
![](../img/icored-b.gif)
Weight:136g(with battery)
![](../img/icored-b.gif)
Operation Environment:
![](../img/icored-b.gif)
Temperature:0?~ +40?
![](../img/icored-b.gif)
Humidity:15% ~ 95%
![](../img/icored-b.gif)
Storage Environment:
![](../img/icored-b.gif)
Temperature:-20?~ +60?
![](../img/icored-b.gif)
Humidity:10% ~ 95%
![](../img/icored-b.gif)
Patient Range
![](../img/icored-b.gif)
Neonate ,Pediatric and Adult
ECG
![](../img/icored-b.gif)
Lead mode:3 leads or 5 leads
![](../img/icored-b.gif)
Option:12 Leads
![](../img/icored-b.gif)
Lead selection:I, II, III, AVR, AVL, AVF, V
![](../img/icored-b.gif)
HR range:15 ~ 300 bpm
![](../img/icored-b.gif)
ECG Waveform:2 channals
![](../img/icored-b.gif)
Accuracy:± 2bpm or ± 2%, which is greater
![](../img/icored-b.gif)
S-T segment detection range:-2.0mv ~ +2.0mv
![](../img/icored-b.gif)
Arrhythmia analysis:13 kinds of arrhythmia
![](../img/icored-b.gif)
Alarm Range:15 ~ 300 bpm
![](http://www.contecmed.com.cn/main/images/UploadFile/2009824151013362.gif)