AccuPulse HandHeld NIBP Simulator
Item No.: NSCD-APHS
$0.00
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300 compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300
HandHeld NIBP Simulator & Digital Manometer
Item No.: Handheld AccuPulse
$0.00    $0.00
Model SP100 SPO2 Module (PN: MO-SP100)
Item No.: MONM-SP100
 

Item Details   ITEM DETAILS  

NT3C MULTPARAMETER PATIENT MONITOR

NT3C Multparameter Patient Monitor,10.4" High Brightness TFT LCD,1-8 Channel Waveform Display,7 Channel ECG Waveform Display; ST SegmentAnalysis; Arrhythmia Analysis,Anti-movement and low perfusion SpO2 Measurement.
NT3C MULTPARAMETER PATIENT MONITOR
Model Number: NT3C
GOLDWEI Item No.: PMNT-NT3C
 
Product Description:

10.4” High Resolution Color TFT LCD
1-8 Channel Waveform Display
7 Leads ECG Waveform Display; ST Segment Analysis
Defibrillation and ESU Protection
OsyCRG diagram, Drug Dose Calculation
Venous Punch
Flexible Parameter Configuration
Applicable for adult, pediatric, and neonatal patients
Options: Thermal recorder, CO2, IBP

 

Product Features :

ECG
ECG Cable: 5 Leadwires ECG cable
Lead section:
lead I, II, III/aVR, aVL, aVF/ V
Gain(mm/mV): 1/4,1/2,1,2,4
Frequency response:
Diagnosis: 0.05 - 100Hz
Monitor: 0.5~40 Hz
Surgery:1.0~25 Hz
Sweep speed(mm/sec):6.25,12.5, 25, 50
Heart rate range: 0-350 BPM
Heart rate accuracy : ± 1 %
ST segment deviation analysis:
-0.8~+0.8mV
ST accuracy : ±0.02mv

Non-Invasive Blood Pressure
Measurement type :
adult, pediatric, neonatal
Measurement range:
Systolic 4.0 - 270mmHg
Diastolic 20 - 200mmHg
Mean 30 - 220mmHg
Accuracy : ±3mmHg or 2 %
Resolution:1mmHg
Protection: over pressure

Pulse Oximetry
SPO2 measurement range: 0 - 100 %
Accuracy: ±2% at 70~100%
(no specification under 70%)
Resolution: 1 %
pulse measurement range:30- 250BPM
Accuracy: ±2 % or 1BPM
Resolution: 1 BPM
Respiration Rate
Measurement range: 0 - 120 BPM
Accuracy: ±1 BPM or 5 %
Resolution: 1 BPM

CO2
Measurement range:
0 % - 10.0 % (in CO2 and et CO2)
Accuracy:
± 2 mm Hg(<5 % Measurement value)
± 10 % (>5 % Measurement value)
Response time: 180 ms

IBP
Channels: 2
range: -40 - +330mmHg
Accuracy: ±4mmHg or ±4%
Resolution: 1mmHg

Environment
Operation Storage
Temperature: 5~40 ℃ -20~70 ℃
Relative humidity: ≤ 80% ≤ 95%

Temperature
Channels: 2
Measurement range: 25~45 ℃
Accuracy: ±0.1 ℃
Resolution: 0.1 ℃
response time: ≤ 3 min

Power Requirements
Input: 98-260 V AC, 50/60Hz
Consumption: ≤ 80VA

There are no documents download yet.

Related Items   RELATED ITEMS  
NT3A Multparameter Patient Monitor

NT3A Multparameter Patient Monitor,10.4" High Brightness TFT LCD,1-8 Channel Waveform Display,7 Channel ECG Waveform Display; ST Segment Analysis; Arrhythmia Analysis,  
Click for More Details 


Item No.: PMNT-NT3A
NT3B Multparameter Patient Monitor

NT3B Multparameter Patient Monitor,12.1" High Brightness TFT LCD,1-8 Channel Waveform Display,•7 Channel ECG Waveform Display; ST Segment Analysis; Arrhythmia Analysis,Anti-movement and low perfusion SpO2 Measurement,Defibrillation and ESU Protection.  
Click for More Details 


Item No.: PMNT-NT3B
NT3E Multparameter Patient Monitor

NT3E Multparameter Patient Monitor,8.4" High Brightness TFT LCD,1-8 Channel Waveform Display,7 Channel ECG Waveform Display; ST Segment Analysis; Arrhythmia Analysis, Anti-movement and low perfusion SpO2 Measurement   
Click for More Details 


Item No.: PMNT-NT3E
NT3F Multparameter Patient Monitor

NT3F Multparameter Patient Monitor,6.4" High Brightness TFT LCD,1-8 Channel Waveform Display, 7 Channel ECG Waveform Display; ST Segment Analysis; Arrhythmia Analysis ,Anti-movement and low perfusion SpO2 Measurement,Pace Pulse Detection,Defibrillation and ESU Protection.   
Click for More Details 


Item No.: PMNT-NT3F
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com