French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300M compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300M
$0.00
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
Item No.: MONM-C200
AccuPulse HandHeld NIBP Simulator
Item No.: NSCD-APHS
$0.00
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300 compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300
 

Item Details   ITEM DETAILS  

MODEL 115A HALF VALUE LAYER ATTENUATOR SET

Determining the Half Value Layer (HVL) of the x-ray beam is the Standard method for specifying the quality of the x-ray beam. For a given kVp, a measurement of the HVL gives information on the total filtration in the x-ray beam. Too little filtration results in unnecessary radiation to the patient and too high of a HVL may require increased kVp and mAs, increasing tube loading and reducing tube life.
MODEL 115A HALF VALUE LAYER ATTENUATOR SET
Model Number: Model 115A
GOLDWEI Item No.: UPGX-115A
 

Half Value Layer

Attenuator Set

Model 115A

 

Determining the Half Value Layer (HVL) of the x-ray beam is the Standard method for specifying the quality of the x-ray beam. For a given kVp, a measurement of the HVL gives information on the total filtration in the x-ray beam. Too little filtration results in unnecessary radiation to the patient and too high of a HVL may require increased kVp and mAs, increasing tube loading and reducing tube life.

 

Gammex 115A Half Value Layer Attenuator Set contains nine sheets of 1100 Aluminum Alloy ranging in thicknesses from 0.1 to 2.0 mm. For your convenience these sheets come in a plastic storage case to help maintain flatness and for ease of storage and transportation

SPECIFICATIONS

Construction ..... 1100 Aluminum Alloy (99.0% Pure)

Size .......................................... 10x10 cm (4x4 in.)

Weight ........................................... 0.2 kg (0.4 lbs.)

Nine Individual Aluminum Sheets

Thickness

(1) ....................................................... 2.0 mm

(2) ....................................................... 1.0 mm

(2) ....................................................... 0.5 mm

(1) ....................................................... 0.2 mm

(3) ....................................................... 0.1 mm


Half Value Layer Attenuator Set Model 115A Determining the Half Value Layer (HVL) of the x-ray beam is the Standard method for specifying the quality of the x-ray beam. For a given kVp, a measurement of the HVL gives information on the total filtration in the x-ray beam. Too little filtration results in unnecessary radiation to the patient and too high of a HVL may require increased kVp and mAs, increasing tube loading and reducing tube life. Gammex 115A Half Value Layer Attenuator Set contains nine sheets of 1100 Aluminum Alloy ranging in thicknesses from 0.1 to 2.0 mm. For your convenience these sheets come in a plastic storage case to help maintain flatness and for ease of storage and transportation

There are no documents download yet.

About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com