French Italian Dutch Spanish Danish German Russian Japanese Korean Simplified Chinese    HOME      COMPANY     PRODUCTS     CATEGORY LIST     WHAT'S NEW!     INFO CENTER     CONTACT US
PRODUCTS
 
   Emergency and Clinics
  Accessories
  Cables/Holter/Electrodes
  ECG Machine
  ECG Series
  Electrosurgical unit
  Fetal Doppler
  Fetal Monitor
  OEM Modules
  Patient Monitor
  Phantoms / Tool Kit
  Pulse Oximeter
  SpO2 Sensors solution
  Testing Measuring Equipme
Category Descriptions

BEST SELLERS
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300M compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300M
$0.00
OEM ETCO2 MODULE (End-tidal CO2) CO2 Module Model C200 for measuring Respiratory Carbon Dioxide CO2 Sensor
Item No.: MONM-C200
AccuPulse HandHeld NIBP Simulator
Item No.: NSCD-APHS
$0.00
Low Flow SIDESTREAM End-Tidal CO2 (ETCO2) MODULE Model C300 compatible with Respironics Loflo CO2 sensor
Item No.: MONM-C300
 

Item Details   ITEM DETAILS  

MINI-DOPPLER FLOW SYSTEM MODEL 1430 LE

The 1430 LE is designed to provide a sonographer with advanced design features that allow for both Doppler and B-Mode ultrasound system tests in one unit. This product consists of the flow system, phantom, and electric flow controller meter.
MINI-DOPPLER FLOW SYSTEM MODEL 1430 LE
Model Number: Model 1430 LE
GOLDWEI Item No.: UPGX-1430LE
 

 

Mini-Doppler

Flow System

Model1430 LE

 

The 1430 LE is designed to provide a sonographer with advanced design features that allow for both Doppler and B-Mode

ultrasound system tests in one unit.  This product consists of the flow system,  phantom, and electric flow controller meter.

 

The B-Mode Phantom component of the 1430 LE is based on our 404GS LE model that provides advanced technology for

measuring image quality on small parts and intracavity ultrasound scanning systems. With added grey scale targets this

small parts phantom also measures contrast, temporal resolution and system linearity. The phantom incorporates the

Gammex Tissue Mimicking gel which provides a smoother background texture and composite film scanning surface that

has improved transmission properties.

 

Unique to the 404GS LE phantom are the closely spaced pin targets. By spacing them closer together, our targets are ideal

for testing a range of high frequency transducers. Resolution patterns and all vertical and horizontal pins are made of

0.1 mm nylon fibers for better detail definition and spatial resolution. Three grey scale targets of -6 dB, +6 dB and +12 dB

relative to the background material are included. A series of anechoic cysts with diameters of 1, 2, 4 and 7

mm permit easy evaluation of system noise and distortion parameters.

 

Two 4 mm vessels are incorporated into the system to meet with FDA Doppler sensitivity recommendations.  One vessel is

parallel to the scan plan at 2 cm, and the other vessel descends 35 degrees from the surface and is used for measuring

Doppler sensitivity and for developing scanner techniques.

 

This self-contained system provides a broad range of available flow rates and test objects. The enhanced microprocessor-

based flow controller meter produces accurate flow rates from 1 to 17 ml/sec corresponding to 0 to 174 cm/sec measurable

velocities with a 1% full scale (FS) accuracy.

 

The 1430 LE provides a realistic test medium for assessing:

• Maximum signal penetration

• Channel isolation of directional discrimination

• Registration accuracy of duplex sample gates and similarities between B-Mode and color flow images.

• Flow rate readout accuracy

 

The Gammex 1430 LE is an all-in-one portable system powered by a built-in LI/ion rechargeable battery. The universal

 charger is included with the system.

 

SPECIFICATIONS

Tissue Mimicking Material

Speed of Sound . . 1540 ±10 m/s

Attenuation . . . . 0.5 or 0.7 ±0.05 dB/cm/MHz

Vessels

Size. . . . . . . . . . 4 mm inside diameter

Location . . . . . . horizontal 2 cm below surface; diagonal at 35 degrees from 1.5 cm below surface

Grey Scale Targets

Contrast . . . . . . . -6, +6, & +12 dB relative

                               to background

Diameter . . . . . . 7 mm

Speed of Sound . . 1540 ±10 m/s

Attenuation . . . . 0.5 or 0.7 ±0.05 dB/cm/MHz

Electronic Flow Control System

Measurable

Velocities . . . . . . 0-174 cm/sec

Pulsatile

Flow Mode . . . . . preprogrammed for

0.25-2 seconds/pulse

Anechoic Cysts

Diameters . . . . . 1, 2, 4, and 7 mm

Speed of Sound . . 1540 ±10 m/s

Attenuation . . . . 0.05 ±0.01 dB/cm/MHz

Pin Targets

Diameter of nylon lines . . . . . 0.1 mm (0.004 in)

Vertical Spacing. . 5 mm at 1 cm to 9 cm deep

Horizontal

Spacing . . . . . . . 10 mm at 1 cm and 5 cm  deep

Blood Mimicking Fluid

Density . . . . . . . 1.03 g/cc

Speed of Sound . . 1550 ±10 m/sec

Scatter Size . . . . 4.7 micron average

Container Construction

Size. . . . . . . . . . 22.9x15.9x21.9 cm  

                           (9x6.25x8.625 in)

Weight. . . . . . . . 4.4 kg (9.5 lbs)

AC Input Voltage.....110 vac - 240 vac

                                   50-60Hz

Battery . . . . . . . LI-ion, rechargeable,

                            universal charger and 

                            plugs included

           

All acoustic measurements at 4.5 MHz, 22° C

,

 


 

Mini-Doppler Flow System Model1430 LE The 1430 LE is designed to provide a sonographer with advanced design features that allow for both Doppler and B-Mode ultrasound system tests in one unit. This product consists of the flow system, phantom, and electric flow controller meter. The B-Mode Phantom component of the 1430 LE is based on our 404GS LE model that provides advanced technology for measuring image quality on small parts and intracavity ultrasound scanning systems. With added grey scale targets this small parts phantom also measures contrast, temporal resolution and system linearity. The phantom incorporates the Gammex Tissue Mimicking gel which provides a smoother background texture and composite film scanning surface that has improved transmission properties. Unique to the 404GS LE phantom are the closely spaced pin targets. By spacing them closer together, our targets are ideal for testing a range of high frequency transducers. Resolution patterns and all vertical and horizontal pins are made of 0.1 mm nylon fibers for better detail definition and spatial resolution. Three grey scale targets of -6 dB, +6 dB and +12 dB relative to the background material are included. A series of anechoic cysts with diameters of 1, 2, 4 and 7 mm permit easy evaluation of system noise and distortion parameters. Two 4 mm vessels are incorporated into the system to meet with FDA Doppler sensitivity recommendations. One vessel is parallel to the scan plan at 2 cm, and the other vessel descends 35 degrees from the surface and is used for measuring Doppler sensitivity and for developing scanner techniques. This self-contained system provides a broad range of available flow rates and test objects. The enhanced microprocessor- based flow controller meter produces accurate flow rates from 1 to 17 ml/sec corresponding to 0 to 174 cm/sec measurable velocities with a 1% full scale (FS) accuracy. The 1430 LE provides a realistic test medium for assessing: ?Maximum signal penetration ?Channel isolation of directional discrimination ?Registration accuracy of duplex sample gates and similarities between B-Mode and color flow images. ?Flow rate readout accuracy The Gammex 1430 LE is an all-in-one portable system powered by a built-in LI/ion rechargeable battery. The universal charger is included with the system.

There are no documents download yet.

Related Items   RELATED ITEMS  
Doppler Flow System Model 1425A LE

The Model 1425A LE Doppler Flow System tests both Doppler and B-mode ultrasound systems using one uniquely designed unit. Gammex combines its low echo matrix with strategically placed line reflectors and anechoic cyst targets at 2, 4, and 6 mm depths. Two 5 mm vessels are incorporated into the system to meet with FDA Doppler sensitivity recommendations. One vessel is parallel to the scan plan at 2 cm, replicating a carotid artery. The other vessel descends 45 degrees from the surface to test Doppler sensitivity and to train different scanner techniques. All of this is combined with a flow controller with microprocessor that has a range of 1 to 12.5 ml/sec within 3% FS accuracy. You can access five programmable test programs and five preset pulse flow patterns with the easy-to-use display panel. This allows for accurate reproducible testing time after time.  
Click for More Details 


Item No.: UPGX-1425A
 
About Us | Latest News | Products| Category List | Terms & Warranty | Manufacturers | Knowledge Base | FAQ | Contact Us |JJWEI Computers | GoldWEI Superfood |
© 2003-2011, GoldWEI Corporation, All Rights Reserved.  Phone: 703-713-0198  Email: sales#goldwei.com